UrbanPro
true
Hariharan Srinivasan Engineering Diploma Tuition trainer in Mumbai

Hariharan Srinivasan

Electrical & Electronic Engineer

Chembur West, Mumbai, India - 400089.

Referral Discount: Get ₹ 500 off when you make a payment to start classes. Get started by Booking a Demo.

Details verified of Hariharan Srinivasan

Identity

Education

Know how UrbanPro verifies Tutor details

Identity is verified based on matching the details uploaded by the Tutor with government databases.

Overview

Design of Electrical and Electronic control panels, Electrical systems, Instrumentation systems,PLC Programming.
Maintenance of high speed automation, Process control equipment in Industry .Inverter Drives, D.C Drives, complex control logics etc.
Customer support system like creating customer base, coordinating, planning and execution of projects ,.spare parts management,MIS System.

Languages Spoken

English

Malayalam

Hindi

Tamil

Education

Mumbai University 1968

Bachelor of Science (B.Sc.)

Address

Chembur West, Mumbai, India - 400089

Verified Info

Phone Verified

Email Verified

Facebook Verified

Report this Profile

Is this listing inaccurate or duplicate? Any other problem?

Please tell us about the problem and we will fix it.

Please describe the problem that you see in this page.

Type the letters as shown below *

Please enter the letters as show below

Teaches

Engineering Diploma Tuition

Class Location

Online (video chat via skype, google hangout etc)

Student's Home

Tutor's Home

Years of Experience in Engineering Diploma Tuition

2

Engineering Diploma Branch

Electrical Engineering Diploma, Electronics

Type of class

Regular Classes

Class strength catered to

Group Classes

Taught in School or College

Yes

BSc Tuition

Class Location

Online (video chat via skype, google hangout etc)

Student's Home

Tutor's Home

Years of Experience in BSc Tuition

4

Electronics Repair Training classes

Class Location

Online (video chat via skype, google hangout etc)

Student's Home

Tutor's Home

Years of Experience in Electronics Repair Training classes

2

Repair item training offered in

Other repairs

Electronics and Communication Classes

Class Location

Online (video chat via skype, google hangout etc)

Student's Home

Tutor's Home

Reviews

No Reviews yet!

FAQs

1. Which Engineering Diploma branches do you tutor for?

Electrical Engineering Diploma and Electronics

2. Do you have any prior teaching experience?

Yes

3. Which classes do you teach?

I teach BSc Tuition, Electronics Repair Training, Electronics and Communication and Engineering Diploma Tuition Classes.

4. Do you provide a demo class?

Yes, I provide a free demo class.

5. How many years of experience do you have?

I have been teaching for 2 years.

Answers by Hariharan Srinivasan (2)

Answered on 23/12/2015 Learn Tuition/Engineering Diploma Tuition

The sub station will have all the protective and metering unit. It will have a Incoming lightning arrestor which will be a ebonite rod with small portion of sharp conducting end which will absorb the energy. The station will have an incoming fuse which will get connected between the incoming 132 kV line... ...more
The sub station will have all the protective and metering unit. It will have a Incoming lightning arrestor which will be a ebonite rod with small portion of sharp conducting end which will absorb the energy. The station will have an incoming fuse which will get connected between the incoming 132 kV line and incoming terminals. Special effort will be made that the terminals are insulated to withstand the 132 kV voltage. From incoming terminal special incoming cable goes to a oil cooled or Vacuum breaker Braker which will trip the line in case of any fault in the outgoing line. Breaker output will go to a 3 phase Transformer which will be a oil cooled Transformer with various protections.Oil Insulation has to withstand the Incoming voltage. Transformer steps down 132 kV voltage to 33kv voltage. Capacity of the Transformer will depend on the load requirement. There will be various protections for the Transformer such as over current,under/over voltage,pressure etc. The output of the Transformer will go through metering units tto monitor volltage,current,power,power factor etc. The output of the Transformer is normally taken through another set of Transmission lines to the destination where voltage will be further stepped down. Normally in the sub station only authorised persons can enter and will be kept locked. To handle any equipment in the sub station special hand gloves having required insulations are kept. Even if we have to replace fuse special rods whose bottom end is grounded is kept. For carrying out any work on the Transformer the breaker is tripped first and after that load end is completely discharged before touching any part.SUB STATION IS NORMALLY KEPT CLEAN DEVOID OF GRASS PAPERS ETC.so accidental fire does not take place
Answers 15 Comments
Dislike Bookmark

Answered on 20/12/2015 Learn Tuition/BCA Tuition

Computer is a Electronic device which perform arithmetic and logical operations. It contains Integrated circuit IC's like Microprocessor which perform logical and arithmatic operations and also contains Read only Memory(ROM) and Random access Memory(RAM) for storing information. For interfacing with... ...more
Computer is a Electronic device which perform arithmetic and logical operations. It contains Integrated circuit IC's like Microprocessor which perform logical and arithmatic operations and also contains Read only Memory(ROM) and Random access Memory(RAM) for storing information. For interfacing with computer there are normally other Integrated Circuits(IC's) known as Input output IC's. All these are normally mounted in a Printed Circuit board (PCB) To access the computer normally external Input devices like key board and mouse are provided. Computer output is normally given to external devices like CRT,Printer etc.
Answers 56 Comments
Dislike Bookmark

Teaches

Engineering Diploma Tuition

Class Location

Online (video chat via skype, google hangout etc)

Student's Home

Tutor's Home

Years of Experience in Engineering Diploma Tuition

2

Engineering Diploma Branch

Electrical Engineering Diploma, Electronics

Type of class

Regular Classes

Class strength catered to

Group Classes

Taught in School or College

Yes

BSc Tuition

Class Location

Online (video chat via skype, google hangout etc)

Student's Home

Tutor's Home

Years of Experience in BSc Tuition

4

Electronics Repair Training classes

Class Location

Online (video chat via skype, google hangout etc)

Student's Home

Tutor's Home

Years of Experience in Electronics Repair Training classes

2

Repair item training offered in

Other repairs

Electronics and Communication Classes

Class Location

Online (video chat via skype, google hangout etc)

Student's Home

Tutor's Home

No Reviews yet!

Answers by Hariharan Srinivasan (2)

Answered on 23/12/2015 Learn Tuition/Engineering Diploma Tuition

The sub station will have all the protective and metering unit. It will have a Incoming lightning arrestor which will be a ebonite rod with small portion of sharp conducting end which will absorb the energy. The station will have an incoming fuse which will get connected between the incoming 132 kV line... ...more
The sub station will have all the protective and metering unit. It will have a Incoming lightning arrestor which will be a ebonite rod with small portion of sharp conducting end which will absorb the energy. The station will have an incoming fuse which will get connected between the incoming 132 kV line and incoming terminals. Special effort will be made that the terminals are insulated to withstand the 132 kV voltage. From incoming terminal special incoming cable goes to a oil cooled or Vacuum breaker Braker which will trip the line in case of any fault in the outgoing line. Breaker output will go to a 3 phase Transformer which will be a oil cooled Transformer with various protections.Oil Insulation has to withstand the Incoming voltage. Transformer steps down 132 kV voltage to 33kv voltage. Capacity of the Transformer will depend on the load requirement. There will be various protections for the Transformer such as over current,under/over voltage,pressure etc. The output of the Transformer will go through metering units tto monitor volltage,current,power,power factor etc. The output of the Transformer is normally taken through another set of Transmission lines to the destination where voltage will be further stepped down. Normally in the sub station only authorised persons can enter and will be kept locked. To handle any equipment in the sub station special hand gloves having required insulations are kept. Even if we have to replace fuse special rods whose bottom end is grounded is kept. For carrying out any work on the Transformer the breaker is tripped first and after that load end is completely discharged before touching any part.SUB STATION IS NORMALLY KEPT CLEAN DEVOID OF GRASS PAPERS ETC.so accidental fire does not take place
Answers 15 Comments
Dislike Bookmark

Answered on 20/12/2015 Learn Tuition/BCA Tuition

Computer is a Electronic device which perform arithmetic and logical operations. It contains Integrated circuit IC's like Microprocessor which perform logical and arithmatic operations and also contains Read only Memory(ROM) and Random access Memory(RAM) for storing information. For interfacing with... ...more
Computer is a Electronic device which perform arithmetic and logical operations. It contains Integrated circuit IC's like Microprocessor which perform logical and arithmatic operations and also contains Read only Memory(ROM) and Random access Memory(RAM) for storing information. For interfacing with computer there are normally other Integrated Circuits(IC's) known as Input output IC's. All these are normally mounted in a Printed Circuit board (PCB) To access the computer normally external Input devices like key board and mouse are provided. Computer output is normally given to external devices like CRT,Printer etc.
Answers 56 Comments
Dislike Bookmark

Hariharan Srinivasan describes himself as Electrical & Electronic Engineer. He conducts classes in BSc Tuition, Electronics Repair Training and Electronics and Communication. Hariharan is located in Chembur West, Mumbai. Hariharan takes at students Home and Regular Classes- at his Home. He has 4 years of teaching experience . Hariharan has completed Bachelor of Science (B.Sc.) from Mumbai University in 1968. HeĀ is well versed in English, Malayalam, Hindi and Tamil.

X

Reply to 's review

Enter your reply*

1500/1500

Please enter your reply

Your reply should contain a minimum of 10 characters

Your reply has been successfully submitted.

Certified

The Certified badge indicates that the Tutor has received good amount of positive feedback from Students.

Different batches available for this Course

This website uses cookies

We use cookies to improve user experience. Choose what cookies you allow us to use. You can read more about our Cookie Policy in our Privacy Policy

Accept All
Decline All

UrbanPro.com is India's largest network of most trusted tutors and institutes. Over 55 lakh students rely on UrbanPro.com, to fulfill their learning requirements across 1,000+ categories. Using UrbanPro.com, parents, and students can compare multiple Tutors and Institutes and choose the one that best suits their requirements. More than 7.5 lakh verified Tutors and Institutes are helping millions of students every day and growing their tutoring business on UrbanPro.com. Whether you are looking for a tutor to learn mathematics, a German language trainer to brush up your German language skills or an institute to upgrade your IT skills, we have got the best selection of Tutors and Training Institutes for you. Read more